2000PC Component Counter

Specifications

Counter Range -59,999 to 59,999
Power 110V AC standard (220V optional)
Dimensions 17" x 9.25" x 10" (432 x 235 x 254mm)
Weight 21lbs (9.5 Kgs)

Details

Get on Top of Your Inventory
The automatic 2000PC SMD parts counter sets up and changes over fast. Count out an entire reel or a specific number of parts to prepare for your next job, and know you've got the right amount, thanks to the 2000PC's Pocket Check and double-check features.
Exclusive "Pocket Check" Tracks Missing Components
Component reels often are missing components, yet most counters cannot detect this condition. The 2000PC counter not only counts the sprocket holes but also has "Pocket Check," which checks each pocket to verify that the component is actually there. If there is a missed part, the machine stops and, before continuing, lets operator know total number of missing components. A digital readout continuously updates the true part count by subtracting missing parts.

As an additional benefit, Pocket Check will stop at the end of new reels as they typically have 5-10 inches of empty pockets at the end of tape reel. This prevents the annoyance of spinning tape whiplash.
Ergonomic and Easy to Use
The design of the 2000PC allows the operator to keep an eye on the LCD screen and the parts as they're being counted at the same time. The machine counts forward and back (for double-checking), or parts can be swiftly spooled back to their original reel.
How It Works
1. Power the machine

After powering up...

...the LCD displays:
SMD CHIP COUNTER
TTL-COU2000
...and changes to:
YY MM DD HH : MM
20 04 12 03 14 : 30
...followed by:
DATA PITCH SET
00000 1

The startup self-checking process is finished at this time.

2. Keys and Settings

TIME key: Clock setting. Press this key shortly will display the date and time on the LCD. Press and hold it for 10 seconds will switch to time setting mode:

YY MM DD HH : MM
20 ** ** ** ** : **

Enter the current date and time. Press the TIME key again to exit. POCKET CHECK key: Press this key will start the missing components detection process. LCD will display a "@" symbol on the upper left corner. The machine stops and beeps if it detects an empty position on the tape. Press this key again will switch to normal operation mode. This function is available only on BC2100PT and BC2200 models.

@ DATA PITCH SET
00000 1

PRINT key: Print components quantity and current time. It can also print bar code. This function is available on BC2100P, BC2100PS and BC2200. It only prints positive numbers.

PITCH key: This key will set the tape pitch. According to EIA-481 standard, available pitches(P:PO ratio) are: 1/2, 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14,...Press the PITCH key repeatedly till the LCD displays the required pitch.

It can be seen that pitch equals the number of puncture holes between two parts (gaps between two holes are 4mm on all tapes). PRESET key: Press this key and enter the desired number. The machine counts to this preset number and stops. Pressing the key again will return to normal mode.

DATA PITCH SET
00000 1 1234

Note: Preset value is invalid if >59999.

CLEAR key: Reset the counter.
START key: Start the counting. Motors start moving, the tape transfers from one reel to the other.
STOP key: Stop counting.
REWIND key: Pressing this key rewinds the tape from the temp reel to the original reel. The counter decrements at the same time. It stops when the counter reaches zero. This also verifies the accuracy of the counting.

3. Operation
  • Mount the reel to be counted on the left side. Make sure there is a temp reel on the right side. Manually lead the tape through the counting gears. Rotate the temp reel till the first component is aligned with the press wheel.
  • Set the pitch value as specified above.
  • Press the START key to start counting. Note: the counter increases or decreases whether it is moved by the motors or manually.
  • Rewind the tape back to the original reel by pressing the REWIND key. Rewinding also verifies the counting result.

Video

2000PC SMD Component Counter with Pocket Check

Previous customers, click here to login.
I Want to See Prices, Request Quotes and/or Buy Online
I Only Want to See Prices

Complete and submit the form below for access to pricing on all our products. (Your browser must allow cookies for this to work.)
Previous customers,
click here to login for pricing
.

* Required
*
*
*
*
*

Previous customers,
click here to login
.


Previous customers, click here to login.
We only need a few more pieces of information to upgrade your access!

Enter your question below and we will get back to you promptly.

Fill out the form below and we will send your colleague a link to this page on your behalf.
Message

Submitting Form. Please Wait...

Successfully completed.

Thank you.

A new user account has been created for you and an email with your user name and password was sent to the email address you supplied.

When you close this form you will be logged in and will be able to see all pricing and request quotes or purchase products.

On future visits simply login.

There was an error submitting your information.
You can contact us directly by phone at 215.830.1200 or send an email to sales@manncorp.com.